General Machines Energy Solutions Products

·

These General Machines Energy Solutions products are ready to be sold to the Guyanese market. Technical support will be provided to customers via the General Machines Energy Solutions technical support team in Guyana.

MAQ DinamiQ 50Hz Generators

MAQ030CP DinamiQ

Stand-by: 30 kVA
Prime: 27 kVA
Engine: Perkins
Alternator: WEG

MAQ050CP DinamiQ

Stand-by: 50 kVA
Prime: 45 kVA
Engine: Perkins
Alternator: WEG

MAQ065CP DinamiQ

Stand-by: 65 kVA
Prime: 59 kVA
Engine: Perkins
Alternator: WEG

MAQ065CC DinamiQ

Stand-by: 65 kVA
Prime: 60 kVA
Engine: Cummins
Alternator: WEG

MAQ105CC DinamiQ

Stand-by: 105 kVA
Prime: 100 kVA
Engine: Cummins
Alternator: WEG

MAQ105CP DinamiQ

Stand-by: 105 kVA
Prime: 95 kVA
Engine: Perkins
Alternator: WEG

MAQ145CF DinamiQ

Stand-by: 145 kVA
Prime: 132 kVA
Engine: FPT
Alternator: WEG

MAQ145CC DinamiQ

Stand-by: 145 kVA
Prime: 130 kVA
Engine: Cummins
Alternator: WEG

MAQ180CF DinamiQ

Stand-by: 180 kVA
Prime: 164 kVA
Engine: FPT
Alternator: WEG

MAQ230CF DinamiQ

Stand-by: 230 kVA
Prime: 209 kVA
Engine: Perkins
Alternator: WEG

MAQ260CF DinamiQ

Stand-by: 260 kVA
Prime: 235 kVA
Engine: FPT
Alternator: WEG

MAQ290CS DinamiQ

Stand-by: 290 kVA
Prime: 264 kVA
Engine: Scania
Alternator: WEG

MAQ330CS DinamiQ

Stand-by: 330 kVA
Prime: 300 kVA
Engine: Scania
Alternator: WEG

MAQ330CV DinamiQ

Stand-by: 330 kVA
Prime: 300 kVA
Engine: VOLVO
Alternator: WEG

MAQ350CV DinamiQ

Stand-by: 350 kVA
Prime: 318 kVA
Engine: VOLVO
Alternator: WEG

MAQ360CS DinamiQ

Stand-by: 360 kVA
Prime: 327 kVA
Engine: Scania
Alternator: WEG

MAQ390CV DinamiQ

Stand-by: 390 kVA
Prime: 355 kVA
Engine: VOLVO
Alternator: WEG

MAQ400CS DinamiQ

Stand-by: 400 kVA
Prime: 364 kVA
Engine: Scania
Alternator: WEG

MAQ430CV DinamiQ

Stand-by: 430 kVA
Prime: 391 kVA
Engine: Volvo
Alternator: WEG

MAQ450CS DinamiQ

Stand-by: 450 kVA
Prime: 409 kVA
Engine: Scania
Alternator: WEG

MAQ500CS DinamiQ

Stand-by: 500 kVA
Prime: 454 kVA
Engine: Scania
Alternator: WEG

MAQ500CV DinamiQ

Stand-by: 500 kVA
Prime: 454 kVA
Engine: Volvo
Alternator: WEG

MAQ540CV DinamiQ

Stand-by: 540 kVA
Prime: 495 kVA
Engine: Volvo
Alternator: WEG

MAQ650CP DinamiQ

Stand-by: 650 kVA
Prime: 590 kVA
Engine: Perkins
Alternator: WEG

MAQ650CV DinamiQ

Stand-by: 650 kVA
Prime: 590 kVA
Engine: Volvo
Alternator: WEG

MAQ700CS DinamiQ

Stand-by: 700 kVA
Prime: 636 kVA
Engine: Scania
Alternator: WEG

MAQ700CV DinamiQ

Stand-by: 700 kVA
Prime: 636 kVA
Engine: Volvo
Alternator: WEG

MAQ770CS DinamiQ

Stand-by: 770 kVA
Prime: 700 kVA
Engine: Scania
Alternator: WEG

MAQ770CV DinamiQ

Stand-by: 770 kVA
Prime: 700 kVA
Engine: Volvo
Alternator: WEG

MAQ PratiQ 50Hz Generators

MAQ030CP PratiQ

Stand-by: 30 kVA
Prime: 27 kVA
Engine: Perkins
Alternator: WEG

MAQ050CP PratiQ

Stand-by: 50 kVA
Prime: 45 kVA
Engine: Perkins
Alternator: WEG

MAQ065CP PratiQ

Stand-by: 65 kVA
Prime: 59 kVA
Engine: Perkins
Alternator: WEG

MAQ105CP PratiQ

Stand-by: 105 kVA
Prime: 95 kVA
Engine: Perkins
Alternator: WEG

MAQ145CF PratiQ

Stand-by: 145 kVA
Prime: 132 kVA
Engine: FPT
Alternator: WEG

MAQ180CF PratiQ

Stand-by: 180 kVA
Prime: 164 kVA
Engine: FPT
Alternator: WEG

MAQ ReboQ 50Hz Generators

MAQ030CP Trailer

Stand-by: 30 kVA
Prime: 27 kVA
Engine: Perkins
Alternator: WEG

MAQ050CP Trailer

Standby: 50 kVA Prime: 50 kVA
Engine: Perkins Alternator: WEG

MAQ065CP Trailer

Stand-by: 65 kVA
Prime: 59 kVA
Engine: Perkins
Alternator: WEG

MAQ105CP Trailer

Stand-by: 105 kVA
Prime: 95 kVA
Engine: Perkins
Alternator: WEG

MAQ145CF Trailer

Stand-by: 145 kVA
Prime: 132 kVA
Engine: FPT
Alternator: WEG

MAQ180CF Trailer

Stand-by: 180 kVA
Prime: 164 kVA
Engine: FPT
Alternator: WEG

MAQ230CF Trailer

Standby: 230 kVA Prime: 209 kVA
Engine: FPT Alternator: WEG

MAQ260CF Trailer

Standby: 260 kVA Prime: 236 kVA
Engine: FPT Alternator: WEG

MAQ PratiQ 60Hz Generators

MAQ040P-PRATIQ-60Hz

Stand-by – 40 kVA
Prime – 36 kVA
Engine – Perkins
Alternator – WEG

MAQ050P-PRATIQ-60Hz

Stand-by – 50 kVA
Prime – 45 kVA
Engine – Perkins
Alternator – WEG

MAQ060P-PRATIQ-60Hz

Stand-by – 60 kVA
Prime – 54 kVA
Engine – Perkins
Alternator – WEG

MAQ075P-PRATIQ-60Hz

Stand-by – 75 kVA
Prime – 68 kVA
Engine – Perkins
Alternator – WEG

MAQ085P-PRATIQ-60Hz

Stand-by – 85 kVA
Prime – 77 kVA
Engine – Perkins
Alternator – WEG

MAQ100P-PRATIQ-60Hz

Stand-by – 100 kVA
Prime – 91 kVA
Engine – Perkins
Alternator – WEG

MAQ125P-PRATIQ-60Hz

Stand-by – 125 kVA
Prime – 114 kVA
Engine – Perkins
Alternator – WEG

MAQ140F-PRATIQ-60Hz

Stand-by – 136 kVA
Prime – 122 kVA
Motor – FPT
Alternator – WEG

MAQ175F-PRATIQ-60Hz

Stand-by – 175 kVA
Prime – 159 kVA
Motor – FPT
Alternator – WEG

MAQ220F-PRATIQ-60Hz

Stand-by – 197 kVA
Prime – 176 kVA
Motor – FPT
Alternator – WEG

MAQ DynamiQ 60Hz Generators

MAQ040P-DINAMIQ

Stand-by – 40 kVA
Prime – 36 kVA
Engine – Perkins
Alternator – WEG

MAQ050P-DINAMIQ

Stand-by – 50 kVA
Prime – 45 kVA
Engine – Perkins
Alternator – WEG

MAQ060P-DINAMIQ

Stand-by – 60 kVA
Prime – 52 kVA
Engine – Perkins
Alternator – WEG

MAQ075P-DINAMIQ

Stand-by – 75 kVA
Prime – 68 kVA
Engine – Perkins
Alternator – WEG

MAQ081C-DINAMIQ

Stand-by – 81 kVA
Prime – 73 kVA
Engine – Cummins
Alternator – WEG

MAQ085P-DINAMIQ

Stand-by – 85 kVA
Prime – 74 kVA
Engine – Perkins
Alternator – WEG

MAQ100P-DINAMIQ

Stand-by – 100 kVA
Prime – 91 kVA
Engine – Perkins
Alternator – WEG

MAQ125P-DINAMIQ

Stand-by – 125 kVA
Prime – 109 kVA
Engine – Perkins
Alternator – WEG

MAQ140C-DINAMIQ

Stand-by – 136 kVA
Prime – 122 kVA
Motor – FPT
Alternator – WEG

MAQ140F-DINAMIQ

Stand-by – 140 kVA
Prime – 130 kVA
Engine – Cummins
Alternator – WEG

MAQ170C-DINAMIQ

Stand-by – 170 kVA
Prime – 150 kVA
Engine – Cummins
Alternator – WEG

MAQ175F-DINAMIQ

Stand-by – 175 kVA
Prime – 160 kVA
Engine – FPT
Alternator – WEG

MAQ220F-DINAMIQ

Standby – 197 kVA Prime – 176 kVA
Engine – FPT Alternator – WEG

MAQ250F-DINAMIQ

Standby – 238 kVA Prime – 214 kVA
Engine – FPT Alternator – WEG

MAQ290F-DINAMIQ

Standby – 290 kVA Prime – 260 kVA
Engine – FPT Alternator – WEG

MAQ310B-DINAMIQ

Standby – 310 kVA Prime – 284 kVA
Engine – Baudouin Alternator – WEG

MAQ330C-DINAMIQ

Standby – 330 kVA Prime – 300 kVA
Engine – Cummins Alternator – WEG

MAQ330-DINAMIQ

Standby – 330 kVA Prime – 300 kVA
Engine – Scania or Volvo Alternator – WEG

MAQ350V DinamiQ

Stand-by – 350 kVA
Prime – 318 kVA
Engine – Volvo
Alternator – WEG

MAQ360S DinamiQ

Stand-by – 360 kVA
Prime – 325 kVA
Engine – Scania
Alternator – WEG

MAQ375C-DINAMIQ

Stand-by – 375 kVA
Prime – 340 kVA
Engine – Cummins
Alternator – WEG

MAQ385B-DINAMIQ

Stand-by – 385 kVA
Prime – 350 kVA
Engine – Baudouin
Alternator – WEG

MAQ400-DINAMIQ

Standby – 400 kVA Prime – 320 kVA
Engine – Scania or Volvo Alternator – WEG


MAQ450-DINAMIQ

Standby – 450 kVA Prime – 410 kVA
Engine – Scania or Volvo Alternator – WEG


MAQ500-DINAMIQ

Standby – 500 kVA Prime – 455 kVA
Engine – Scania or Volvo Alternator – WEG


MAQ500C-DINAMIQ

Standby – 500 kVA Prime – 450 kVA
Engine – Cummins Alternator – WEG


MAQ550B-DINAMIQ

Stand-by – 550 kVA
Prime – 500 kVA
Engine – Baudoin
Alternator – WEG


MAQ550-DINAMIQ

Stand-by – 550 kVA
Prime – 500 kVA
Engine – Scania or Volvo
Alternator – WEG


MAQ625S-DINAMIQ

Stand-by – 625 kVA
Prime – 566 kVA
Engine – Scania
Alternator – WEG


MAQ640V-DINAMIQ

Stand-by – 640 kVA
Prime – 570 kVA
Engine – Volvo
Alternator – WEG


MAQ680V-DINAMIQ

Stand-by – 680 kVA
Prime – 625 kVA
Engine – Volvo
Alternator – WEG


MAQ720S-DINAMIQ

Stand-by – 720 kVA
Prime – 652 kVA
Engine – Scania or Perkins
Alternator – WEG


MAQ750-DINAMIQ

Stand-by – 750 kVA
Prime – 680 kVA
Engine – Volvo or Perkins
Alternator – WEG


MAQ750S-DINAMIQ

Stand-by – 770 kVA
Prime – 700 kVA
Engine – Scania
Alternator – WEG


MAQ800V-DINAMIQ

Stand-by – 800 kVA
Prime – 700 kVA
Engine – Volvo
Alternator – WEG

MAQ ReboQ 60Hz Generators


MAQ040P-REBOQ-60Hz

Stand-by – 40 kVA
Prime – 36 kVA
Engine – Perkins
Alternator – WEG


MAQ050P-REBOQ-60Hz

Stand-by – 50 kVA
Prime – 45 kVA
Engine – Perkins
Alternator – WEG


MAQ060P-REBOQ-60Hz

Stand-by – 60 kVA
Prime – 54 kVA
Engine – Perkins
Alternator – WEG


MAQ075P-REBOQ-60Hz

Stand-by – 75 kVA
Prime – 68 kVA
Engine – Perkins
Alternator – WEG


MAQ085P-REBOQ-60Hz

Stand-by – 85 kVA
Prime – 77 kVA
Engine – Perkins
Alternator – WEG


MAQ100P-REBOQ-60Hz

Stand-by – 100 kVA
Prime – 91 kVA
Engine – Perkins
Alternator – WEG


MAQ125P-REBOQ-60Hz

Stand-by – 125 kVA
Prime – 110 kVA
Engine – Perkins
Alternator – WEG


MAQ140F-REBOQ-60Hz

Stand-by – 140 kVA
Prime – 127 kVA
Engine – FPT
Alternator – WEG


MAQ175F-REBOQ-60Hz

Stand-by – 175 kVA
Prime – 160 kVA
Engine – FPT
Alternator – WEG


MAQ220F-REBOQ-60Hz

Stand-by – 220 kVA
Prime – 200 kVA
Engine – FPT
Alternator – WEG


MAQ250F-REBOQ-60Hz

Standby – 250 kVA Prime – 227 kVA
Engine – FPT Alternator – WEG


MAQ290F-REBOQ-60Hz

Standby – 290 kVA Prime – 260 kVA
Engine – FPT Alternator – WEG


MAQ290F-REBOQ-60Hz

Standby – 290 kVA Prime – 260 kVA
Engine – FPT Alternator – WEG

MAQ THIS 60Hz Generators


MAQ040P-REBOQ-60Hz

Stand-by – 40 kVA
Prime – 36 kVA
Engine – Perkins
Alternator – WEG


MAQ050P-REBOQ-60Hz

Stand-by – 50 kVA
Prime – 45 kVA
Engine – Perkins
Alternator – WEG


MAQ060P-REBOQ-60Hz

Stand-by – 60 kVA
Prime – 54 kVA
Engine – Perkins
Alternator – WEG

MAQ075P-REBOQ-60Hz

Stand-by – 75 kVA
Prime – 68 kVA
Engine – Perkins
Alternator – WEG

MAQ085P-REBOQ-60Hz

Stand-by – 85 kVA
Prime – 77 kVA
Engine – Perkins
Alternator – WEG

MAQ100P-REBOQ-60Hz

Stand-by – 100 kVA
Prime – 91 kVA
Engine – Perkins
Alternator – WEG

MAQ125P-REBOQ-60Hz

Stand-by – 125 kVA
Prime – 110 kVA
Engine – Perkins
Alternator – WEG

MAQ140F-REBOQ-60Hz

Stand-by – 140 kVA
Prime – 127 kVA
Engine – FPT
Alternator – WEG

MAQ175F-REBOQ-60Hz

Stand-by – 175 kVA
Prime – 160 kVA
Engine – FPT
Alternator – WEG

MAQ220F-REBOQ-60Hz

Stand-by – 220 kVA
Prime – 200 kVA
Engine – FPT
Alternator – WEG

MAQ250F-REBOQ-60Hz

Stand-by – 250 kVA
Prime – 227 kVA
Engine – FPT
Alternator – WEG

MAQ500S-DESTAQ-60Hz

Stand-by: 500 kVA
Prime: 455 kVA
Engine: Scania
Alternator: WEG

MAQ500V-DESTAQ-60Hz

Stand-by: 500 kVA
Prime: 455 kVA
Engine: Volvo
Alternator: WEG

MAQ550S-DESTAQ-60Hz

Stand-by: 550 kVA
Prime: 500 kVA
Engine: Scania
Alternator: WEG

MAQ550V-DESTAQ-60Hz

Stand-by: 550 kVA
Prime: 500 kVA
Engine: Volvo
Alternator: WEG

MAQ625S-DESTAQ-60Hz

Stand-by: 625 kVA
Prime: 566 kVA
Engine: Scania
Alternator: WEG

MAQ640V-DESTAQ-60Hz

Stand-by: 640 kVA
Prime: 570 kVA
Engine: Volvo
Alternator: WEG

MAQ680V-DESTAQ-60Hz

Stand-by: 680 kVA
Prime: 625 kVA
Engine: Volvo
Alternator: WEG

MAQ680MAQ720S-DESTAQ-60Hz

Stand-by: 720 kVA
Prime: 652 kVA
Engine: Scania
Alternator: WEG

MAQ750P-DESTAQ-60Hz

Stand-by: 750 kVA
Prime: 680 kVA
Engine: Perkins
Alternator: WEG

MAQ750V-DESTAQ-60Hz

Stand-by: 750 kVA
Prime: 680 kVA
Engine: Volvo
Alternator: WEG

MAQ770 S-DESTAQ-60Hz

Standby: 770 kVA Prime: 700 kVA
Engine: SCANIA Alternator: WEG


MAQ800V-DESTAQ-60Hz

Standby: 800 kVA Prime: 700 kVA
Engine: Volvo Alternator: WEG

MAQ FortiQ 60Hz Generators


MAQ040P-FortiQ-60Hz

Stand-by: 40 kVA
Prime: 36 kVA
Engine: Perkins
Alternator: WEG


MAQ050P-FortiQ-60Hz

Stand-by: 50 kVA
Prime: 45 kVA
Engine: Perkins
Alternator: WEG


MAQ075-FortiQ-60Hz

Stand-by: 75 kVA
Prime: 68 kVA
Engine: Perkins
Alternator: WEG


MAQ085P-FortiQ-60Hz

Stand-by: 85 kVA
Prime: 74 kVA
Engine: Perkins
Alternator: WEG

MAQ100P-FortiQ-60Hz

Stand-by: 100 kVA
Prime: 91 kVA
Engine: Perkins
Alternator: WEG

MAQ125P-FortiQ-60Hz

Stand-by: 125 kVA
Prime: 109 kVA
Engine: Perkins
Alternator: WEG

MAQ140F-FortiQ-60Hz

Stand-by: 136 kVA
Prime: 122 kVA
Engine: FPT
Alternator: WEG

MAQ175F-FortiQ-60Hz

Stand-by: 175 kVA
Prime: 160 kVA
Engine: FPT
Alternator: WEG

MAQ220F-FortiQ-60Hz

Stand-by: 220 kVA
Prime: 200 kVA
Engine: FPT
Alternator: WEG

MAQ250F-FortiQ-60Hz

Stand-by: 250 kVA
Prime: 227 kVA
Engine: FPT
Alternator: WEG

MAQ290F-FortiQ-60Hz

Stand-by: 290 kVA
Prime: 260 kVA
Engine: FPT
Alternator: WEG

MAQ330S-FortiQ-60Hz

Stand-by: 330 kVA
Prime: 300 kVA
Engine: Scania
Alternator: WEG

MAQ330V-FortiQ-60Hz

Stand-by: 330 kVA
Prime: 300 kVA
Engine: Scania
Alternator: WEG

MAQ350V-FortiQ-60Hz

Stand-by: 350 kVA
Prime: 315 kVA
Engine: Scania
Alternator: WEG

MAQ360S-FortiQ-60Hz

Stand-by: 360 kVA
Prime: 320 kVA
Engine: Scania
Alternator: WEG

MAQ400S-FortiQ-60Hz

Stand-by: 400 kVA
Prime: 360 kVA
Engine: Scania
Alternator: WEG

MAQ400V-FortiQ-60Hz

Stand-by: 400 kVA
Prime: 360 kVA
Engine: Scania
Alternator: WEG

MAQ450S-FortiQ-60Hz

Stand-by: 450 kVA
Prime: 400 kVA
Engine: Scania
Alternator: WEG


MAQ450V-FortiQ-60Hz

Stand-by: 450 kVA
Prime: 400 kVA
Engine: Scania
Alternator: WEG


MAQ500S-FortiQ-60Hz

Stand-by: 500 kVA
Prime: 450 kVA
Engine: Scania
Alternator: WEG


MAQ500V-FortiQ-60Hz

Stand-by: 500 kVA
Prime: 450 kVA
Engine: VOLVO
Alternator: WEG


MAQ550S-FortiQ-60Hz

Stand-by: 550 kVA
Prime: 500 kVA
Engine: Scania
Alternator: WEG


MAQ550V-FortiQ-60Hz

Stand-by: 550 kVA
Prime: 500 kVA
Engine: VOLVO
Alternator: WEG



MAQ625S-FortiQ-60Hz

Stand-by: 625 kVA
Prime: 565 kVA
Engine: Scania
Alternator: WEG



MAQ640V-FortiQ-60Hz

Stand-by: 640 kVA
Prime: 580 kVA
Engine: VOLVO
Alternator: WEG



MAQ680V-FortiQ-60Hz

Stand-by: 680 kVA
Prime: 625 kVA
Engine: VOLVO
Alternator: WEG



MAQ720S-FortiQ-60Hz

Stand-by: 720 kVA
Prime: 640 kVA
Engine: Scania
Alternator: WEG



MAQ750P-FortiQ-60Hz

Stand-by: 750 kVA
Prime: 680 kVA
Engine: Perkins
Alternator: WEG



MAQ750V-FortiQ-60Hz

Stand-by: 750 kVA
Prime: 680 kVA
Engine: Volvo
Alternator: WEG



MAQ770S-FortiQ-60Hz

Stand-by: 770 kVA
Prime: 690 kVA
Engine: Scania
Alternator: WEG



MAQ800V-FortiQ-60Hz

Stand-by: 800 kVA
Prime: 720 kVA
Engine: Scania
Alternator: WEG



MAQ060P-FORTIQ

Stand-by: 60 kVA
Prime: 52 kVA
Engine: Perkins
Alternator: WEG

DuomaQ 60Hz Generators



DUOMAQ900S

Stand-by: 900 kVA
Prime: 818 kVA
Engine: Scania
Alternator: WEG



DUOMAQ1000S

Stand-by: 1000 kVA
Prime: 909 kVA
Engine: Scania
Alternator: WEG



DUOMAQ1100S

Stand-by: 1100 kVA
Prime: 1000 kVA
Engine: Scania
Alternator: WEG



DUOMAQ1250S

Stand-by: 1250 kVA
Prime: 1136 kVA
Engine: Scania
Alternator: WEG

CONTROLS FOR GENERATOR SETS IN APPLICATION SIMPLE TO GENERATION PLANTS + NUMEROUS FUNCTIONS AND CONNECTIVITY

* We are recognized as one of the leading manufacturers of generator groups in Brazil.

* The manufacturer designs, manufactures and markets a range of generator sets from 40 kVA to 800kVA that meet all power needs and that can be adapted to all applications. Thanks to the expertise of its engineering, and to meet the more specific demands of customers, we offer the market a range of controllers with different functions.

General Machines Energy Solutions Original Equipment

You can customize your Power Generator with the wide variety of mechanical accessories from General Machines Energy Solutions. These products are developed and certified by the General Machines Energy Solutions engineering team in Brazil. Easy to apply, they are sized to ensure your generator meets all your needs.

With General Machines Energy Solutions mechanical accessories, you increase the productivity and efficiency of your Power Generator, whatever the type of operation.

Among the Original General Machines Energy Solutions equipment, you will find:

  • Fuel tanks
  • Retention basins
  • Mechanical buoys
  • Fuel level switches

Among the Original General Machines Energy Solutions equipment, you will find:

  • Noise attenuators
  • Acoustic doors
  • Rain shutters
  • Acoustic rooms

General Machines Energy Solutions® designs and manufactures electrical panels for generator sets and transfer systems. Our electrical panels are designed to distribute the generated energy with maximum efficiency and safety. General Machines Energy Solutions team of engineers and experienced technicians analyze and customize designs to meet your needs.

Types of panels:

  • Generator Control Panel (GCP) – Its purpose is to safely and quickly start up machines and motors.
  • Generator Power Panel – Its function is to protect the generator set. Our panels use circuit breakers for disconnection operation and protection against possible overloads or short circuits.
  • Control and Parallelism Panel (QCP) – Panel with generator control for power plant operation and motorized circuit breaker for synchronization.
  • Distribution Panel – Ensures the supply of electrical power to all areas.
  • Automatic Transfer Switch (ATS) – Using two power sources (mains and generator set), the ATS energizes the load by switching and selecting between the appropriate power sources. These switches may include:
    – Motorized changeover switch
    – A pair of contactors
    – A pair of motorized circuit breakers
  • Power Plant Management Panel (QGU)
  • Elevator selection panel
  • Auxiliary services chart
  • Protection relay panel
  • Electric pump panel
  • TTA/PTTA generator selection panel – Panels that make up your electrical installation complying with the following standards: NR-10; NBR IEC 60439-1 and NBR IEC 60439-3.

Open Transfer Frame

  • Automatic Start
  • Switch
  • Accountants

Ramp Transfer Panel

  • Automatic Start
  • Continuous parallelism
  • Circuit breakers

Open Transfer Frame

  • Voltage and frequency stability and synchronization
  • Load management
guest

0 Comments
Oldest
Newest Most Voted
0
Would love your thoughts, please comment.x
()
x